Why is my heat pump not heating in San Mateo?

You turn the heat on and the air coming out feels cool, or barely warm, and it's not keeping the house comfortable. In San Mateo winters stay mild, so a heat pump should be able to keep up without much strain. When it can't, something specific is wrong rather than the system just being overworked by cold weather the way it might be elsewhere.

It's likely low refrigerant, a failed reversing valve, or a frozen outdoor coil

A heat pump moves heat from the outside air into your house, and it needs a full charge of refrigerant and a working reversing valve to do that. If refrigerant has leaked out, the system can't pull in enough heat to warm the air moving through your ducts. If the reversing valve is stuck, the unit may still be running in cooling mode without you noticing. Winters in San Mateo are mild, so the outdoor coil shouldn't ice over under normal conditions. When it does, that points to a mechanical problem, not the weather. Since most homes here heat with gas, a gas furnace handles the bulk of the work in many houses, so a heat pump that stops heating often shows up as a secondary system falling short, but the same fix applies either way.

An outdoor condenser unit encased in thick ice stands on snow beside a house with horizontal siding and exterior pipes, with bare trees and a sunset glow in the background.

You go out for the paper before work and see it: the outdoor unit crusted in ice, thick along the coil and down the sides of the cabinet. It's just past dawn, cold enough that your breath shows, and the side yard is still in shadow. Inside, the air from the vents has been running cool for days. The fan is turning but the coil underneath the ice isn't doing anything useful anymore. You crouch down and touch it, and the cold goes through your fingers in a second. Somewhere in the house the thermostat still reads the temperature you set it to, climbing slower than it should, if it's climbing at all.

A gray outdoor condenser unit on a concrete pad beside a house with horizontal lap siding, connected by conduit and lines to a wall-mounted disconnect box, with a shrub and gravel bed to the left.
This unit runs clean and clear, with nothing blocking the coil or the fan behind the grille.
An outdoor air conditioner condenser unit on a concrete pad beside a house with horizontal lap siding, with refrigerant lines and a gray electrical disconnect box on the wall, surrounded by bare dirt.
Dirt and debris packed into the coil guard like this block airflow and make the unit work harder to heat your home.

A heat pump doesn't make heat the way a furnace does. It pulls warmth out of the outside air and moves it inside, so the air at your registers runs warmer than the room, not hot like a gas furnace. Inside the outdoor unit, a valve decides whether the system heats or cools. If that reversing valve sticks, the thermostat can call for heat all it wants and the unit stays on the wrong setting. Some frost on the outdoor coil on a cold morning is nothing to worry about. The system should sense it, run a short defrost cycle, and clear the coil in about ten minutes. During that cycle the outdoor fan shuts off and the system runs backward for a bit, so don't be surprised if the air inside turns cool for a few minutes. If it stays cold outside longer than the heat pump can keep up with on its own, the thermostat is supposed to bring in auxiliary heat. A sensor reading the temperature wrong can keep that from happening. And if the refrigerant charge is low, the coil can't pull in as much heat no matter how well everything else runs.

How a heat pump actually heats

  • A heat pump moves heat from the outside air into your house instead of burning fuel to make it, which is why it can't warm a room as fast as a gas furnace.
  • The reversing valve switches the system between heating and cooling, and when it sticks, the unit keeps running in the wrong mode no matter what the thermostat says.
  • A thin coat of frost on the outdoor coil in the morning is normal, but the unit should run a defrost cycle and clear it within about ten minutes.
  • During a normal defrost cycle the outdoor fan stops, the system briefly reverses, and the indoor air may feel cool or even cold for a few minutes.
  • The thermostat has to call for auxiliary or emergency heat when the outdoor temperature drops low enough that the heat pump alone can't keep up, and a miscalibrated sensor can block that call.
  • Refrigerant charge affects how much heat the coil can pull from the outside air, so a system running low will heat weakly even when every part is working.
A smiling man in a blue denim shirt over a white tee sits at a light stone kitchen counter with a grey mug and a bowl of oranges and bananas, with pendant lights and shelving behind him.
A smiling bearded man in a grey long-sleeved shirt sits at a kitchen counter with a dark mug, with a dining table, pendant light and glass doors onto greenery behind him.
A bearded man in a dark green knit sweater smiles and looks off to the side while standing at a kitchen counter with a white mug of coffee, with open shelving, a potted tree, and a dining table near large windows behind him.
A man with dark curly hair in a dark green sweater stands smiling and looking to the side in a kitchen with white cabinets, a potted plant, a stone countertop with a ceramic mug, and a dining area with framed art in the background.
A gray outdoor condenser unit of an air conditioner or heat pump sits on a concrete pad beside a house with horizontal lap siding, with a wall-mounted disconnect box and conduit above it, mulched beds, shrubs and grass nearby.

Hand off the search today

A licensed pro who works in San Mateo County gets your request.

After this form, you can stop searching for a heat pump pro.

I'm done searching

It costs nothing to send, and you don't have to hire anyone.

Why does a heat pump struggle on a mild San Mateo winter night?

  • Winter nights average 43°F

    Nights this cold mean the outdoor coil is pulling heat from thin air, so a weak unit falls behind right when you need it most.

  • Heat runs November through May

    Seven months of the year your heat pump is the one keeping the house warm, so a system that can't keep up costs you comfort for most of the year.

  • Power here costs 38.23 cents per kilowatt-hour

    At this rate, a heat pump straining to make heat it should make easily runs up a bill you'll notice fast.

NOAA nClimDiv 1991-2020 · EIA-861 2025

Why the outdoor unit keeps running

A heat pump doesn't shut off once the house feels warm the way a furnace might. It cycles slower and runs longer, pulling heat out of outside air even when that air is in the 40s. That's normal. What's not normal is a unit that runs constantly and never brings the house up to temperature. If the outdoor fan is turning, the unit sounds like it's working, and the house still isn't warming, the problem is in how much heat it's actually moving, not whether it's running at all.

What the thermostat can tell you

Most heat pump thermostats have an emergency heat setting, separate from the normal heat setting. If switching to emergency heat warms the house but regular heat doesn't, that points to the outdoor unit itself rather than the thermostat or ductwork. It's a quick check you can do before anyone comes out, and it narrows down where the problem sits. Leaving it on emergency heat for days at a time isn't a fix, since that backup heat source costs more to run, but it tells a contractor where to start looking.

Winter nights average 43°F

At 43°F, a heat pump here still has enough warmth in the air to pull from. It should run steady through the night without icing over or losing ground. If the air coming out feels cool on a night like that, the unit isn't working the way it should.

NOAA nClimDiv 1991-2020

Calling now versus waiting it out

A heat pump that's struggling but still putting out some warm air can be looked at before it fails outright. Someone who works on these units knows the common points of failure, a low refrigerant charge, a stuck reversing valve, a failed defrost board, and can usually tell within a short visit which one you're dealing with. Catching it at this stage often means a simpler repair, and it means you're not without heat on a night when San Mateo temperatures drop into the 40s. The unit stays in your control instead of the weather's.

Waiting until it quits entirely

If you wait, the same worn part keeps working against itself until something gives out. A reversing valve that sticks occasionally will stick for good. A compressor straining to keep up can burn out rather than just underperform. At that point the repair is bigger, and you're choosing between a cold house and a rushed decision. Most homes here heat with gas as backup or as the main source, so a failed heat pump isn't always a dark, cold house, but it is a system running harder than it should, and a bill that shows it.

A bearded man in a dark blue T-shirt sits on a gray couch, smiling and looking down to his left, with a bookshelf and a bright window behind him.
A bearded man in a plaid flannel shirt stands indoors beside a wood-framed, frost-covered window, looking outside, with a steaming brown mug on the sill and a wooden cabinet behind him.
A two-story house with light beige horizontal siding, a gabled roof, a small covered front porch with dark door, and shrubs along the foundation, set behind a mown lawn and wet sidewalk with large leafy trees on both sides.

San Mateo County summers hold a dew point around 54°F, which is dry for California and dry compared to most of the country. That matters for your heat pump in winter too, not just summer. Dry air holds less moisture, and less moisture in the air outside means less frost forming on the outdoor coil when temperatures drop at night. If you're seeing heavy ice on the unit here, it points to something wrong with the system itself, a refrigerant leak or a defrost control that isn't cycling, rather than just damp air doing what damp air does.

NASA POWER T2MDEW

A heat pump that isn't warming the house usually comes down to one of a few things: a low refrigerant charge, a reversing valve stuck in the wrong position, a sensor or defrost board that's misreading conditions, or ice built up on the outdoor coil that isn't melting off on its own. None of those get better by running the system longer. Someone who works on heat pumps in San Mateo County sees these same failures through the mild, wet winters here and knows which one is likely before the panels even come off. Getting the right contractor out, one licensed to work on your system and familiar with this equipment in this climate, means a single visit instead of a string of calls to different companies trying to find someone who knows what they're looking at. You don't need to diagnose it yourself. You just need to get it in front of someone who's seen it before.

A house with a gray metal gabled roof and chimney stands among trees in the foreground, overlooking dry golden hills, hazy ridgelines, and distant water under a pale sky.

Hand off the heat pump problem

Hand it over

No charge to send it. You decide if you hire them.