How a Gas Furnace Actually Lights
- A gas furnace lights in a set order: thermostat calls, inducer motor spins up, igniter heats, gas valve opens, flame sensor confirms the flame is real.
- If the flame sensor doesn't prove a flame within about two seconds of the gas valve opening, the control board shuts the valve again as a safety check.
- A furnace that tries three times and then locks out is doing what it's built to do, not failing randomly, and it needs a reset at the breaker or thermostat before it tries again.
- The flame sensor is a thin metal rod near the burners, not the igniter, and a layer of soot on it is enough to stop it from sensing anything.
- Short cycling, where the furnace fires and quits within a minute, usually traces back to that sensor or to a clogged filter starving the burners of air.
- Repeated lockouts put wear on the igniter and the gas valve each time they cycle, so a furnace doing this needs attention before one of those parts fails outright.
A gas furnace doesn't just dump gas in and light a match to it. There's an order. The thermostat calls for heat, the inducer motor spins up first to clear the heat exchanger, and only then does the igniter start heating. Once the igniter is hot enough, the gas valve opens. Within about two seconds, a small metal rod near the burners called the flame sensor has to prove a real flame is burning. If it doesn't, the control board cuts the gas valve again right away. That's not a malfunction. It's the safety check working as designed, because an open gas valve with no flame is not something a furnace is allowed to risk.
If this happens three times in a row, most furnaces lock out and won't try a fourth time until someone resets them at the breaker or the thermostat. People sometimes read this as the furnace being broken. More often it means the flame sensor has a layer of soot on it thin enough to see past but thick enough to block it from reading a flame at all. The same thing causes short cycling, where the furnace fires, runs for under a minute, and shuts off again. a clogged filter can cause the same pattern by starving the burners of air. Either way, every lockout cycle puts extra wear on the igniter and the gas valve, both of which have a limited number of times they can fire before they fail.